Logger type CTD with fast optical DO sensor
Product Number:JFE RINKO Profiler
			● Fast-response DO sensor (90%:less than 1 s in air)
● Built-in memory
● Built-in rechargeable lithium-ion batteries
● Vertical data sampling at 10cm pitch
● Continuous vertical data sampling at 0.5m s-1
● Corrosion prevention (titanium case)
● Light weight design (approx. 2.0kg in air and 1.0kg in waater)
        
        				
		
		
		
    ● Built-in memory
● Built-in rechargeable lithium-ion batteries
● Vertical data sampling at 10cm pitch
● Continuous vertical data sampling at 0.5m s-1
● Corrosion prevention (titanium case)
● Light weight design (approx. 2.0kg in air and 1.0kg in waater)
		The RINKO-Profiler is a CTD with a fast-responding DO sensor as standard. The fast response time (0.4 s) reduces observation time, while achieving a detailed DO vertical distribution. You can measure water temperature, salinity and DO vertical profile measurement easily without a cable due to light weight (approx. 1.0 kg in water) and built-in recording design (The ASTD 152 model can also measure chlorophyll and turbidity as well). The high-capacity internal memory (1 GB) allows for recording up to 1,000 profiles (of 100 m depth at 0.1 s of sampling rate). Each profile is dated using the instrument internal clock. The power source is a rechargeable lithium battery that allows continuous use up to 10 h and 3 h of charge time. The RINKO-Profiler communicates between the interface and
ers the PC recharging the battery without opening Chlorophyll Turbidity the pressure case. The RINKO-Profiler serie
have two types of interfaces: a PC communication model and a model that comes with a printer.
相關paper
    
        ers the PC recharging the battery without opening Chlorophyll Turbidity the pressure case. The RINKO-Profiler serie
have two types of interfaces: a PC communication model and a model that comes with a printer.
相關paper
- Flores Melo, X., Martín J., Kerdel L., Bourrin F., Colloca C.B., Menniti C., de Madron X.D., (2020) Particle Dynamics in Ushuaia Bay (Tierra del Fuego)-Potential Effect on Dissolved Oxygen Depletion. Water, 12, 324. DOI: 10.3390/w12020324
 
| Parameter | Range | Accuracy | Response Time | 
| Temperature | -3~45℃ | ±0.01℃ | 0.2s | 
| Dissolved Oxygen | Air saturation:0~200% | ±2% FS | 0.4s(2) | 
| Depth | 0~600m(1) | ±0.3% FS | 0.2s | 
| Conductivity | 0.5~75 mS cm-1 | ±0.01 mS cm-1 | 0.2s | 
| Salinity | 2~42 | - | 0.2s | 
| Turbidity | 0~1000 FTU | ±2% MV or ±0.3 FTU | 0.2s | 
| Chlorophyll | 0~400 ppb | ±1% FS | 0.2s | 
(2) 63% response time (at 25℃ in air)
    
                            
    
    