RBRmaestro³ C.T.D multi-channel logger

商品編號:RBRmaestro³ C.T.D multi-channel logger
Our most flexible, option-packed, multi-channel logger.

Five to ten integrated channels
240M readings
Up to 16Hz sampling
USB-C download
Twist activation
Wi-Fi ready
Realtime communications

Available sensors:

Conductivity (C), Temperature (T), Pressure (D), Dissolved Oxygen (DO), Optical Dissolved Oxygen (ODO), Photosynthetically Active Radiation (PAR), Radiometer (rad), Turbidity (Tu), Fluorescence (Fl), pH, Oxidation-Reduction Potential (ORP), Methane, Carbon Dioxide, Transmittance, Voltage
The RBRmaestro³ multi-channel instrument supports up to ten sensors on a single platform. A diversity of sensor configurations allows it to be fine-tuned for a wide variety of applications. Variants with pressure, temperature, conductivity, radiometer, PAR, and turbidity sensors are also available in titanium housing, designed to endure harsh conditions.

Available for both autonomous deployment and water column profiling, the RBRmaestro³ supports data and power connections for remote access. All calibration coefficients are stored in the instrument, and re-calibration by the end-user is possible for several sensors.

Optional mooring clamps and cages are available. Rugged transit cases are recommended.
Physical
Storage 240M readings
Power 8 AA cells (alkaline or lithium iron)
External power 4.5 to 30V
Communication USB-C or RS-232/485
Clock drift ±60 seconds/year
Housing Plastic or titanium
Diameter 63.3mm (plastic), 60.3mm (Ti)
Length Configuration dependent
Weight Configuration dependent
Depth rating Up to 6000m (configuration dependent)
Sampling rate 2Hz; options up to 16Hz
Conductivity
Range 0-85mS/cm
Initial accuracy ±0.003mS/cm
Typical stability 0.010mS/cm/year
Resolution 0.001mS/cm
Temperature
Range-5°C to 35°C
Initial accuracy ±0.002°C
Resolution <0.00005°C
Time constant <0.1s | fast, <1s standard
Typical stability 0.002°C/year
1A wider temperature range is available upon request. Contact RBR for more information.
Pressure (Depth)
Range20 / 50 / 100 / 200 / 500 / 750dbar (plastic)
1000 / 2000 / 4000 / 6000dbar (Ti)
Initial accuracy ±0.05% full scale
Resolution <0.001% full scale
Time constant <0.01s
Typical stability ±0.05% full scale per year
2Recommended depth for wave measurements is less than 50m.
Turbidity (Seapoint®)
Light source 880nm
Time Constant 0.1s
Linearity <2% deviation for 0-1250 FTU
Fluorescence (Seapoint®)
Excitation 470nm / 685nm (chlorophyll a)
370nm / 440nm (cDOM)
Time Constant 0.1s
Dissolved Oxygen Sensor (Oxyguard®)
Range 0 to 600%
Initial accuracy ±2% O2 saturation
Resolution 1% of saturation
Response Time ~10s, 90% step change at 20°C
Contact RBR for other sensor options.